Options
Title
Laboratory evaluation of dripper performance
Fields of Research (FoR) 2008:
Author(s)
Publication Date
2016
Socio-Economic Objective (SEO) 2008
Abstract
The catch can method is traditionally used for evaluating performance of drip systems. Two variations of this method are commonly applied in laboratory testing of drippers: the sequential and the simultaneous method. This study compared uniformity and measurement uncertainty of the two methods, with the overall aim of improving irrigation water management. The simultaneous method was found to have a lower coefficient of variation(Cν) and measurement uncertainty, indicating that it is more accurate than the sequential method. In all the tests, however, the Cν was determined to be <5%, which is acceptable as per the current reference standard.
Publication Type
Journal Article
Source of Publication
Flow Measurement and Instrumentation, v.50, p. 261-268
Publisher
Elsevier Ltd
Place of Publication
United Kingdom
ISSN
1873-6998
0955-5986
Fields of Research (FoR) 2020
Peer Reviewed
Yes
HERDC Category Description
Peer Reviewed
Yes
Statistics to Oct 2018:
Visitors: 25<br />Views: 25<br />Downloads: 0
Permanent link to this record